<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-04 15-37-28
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 60 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 69 kHz 14367 14,5611
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,5 dBr 5,12 dBr 6,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 69 kHz MIN: 9 kHz % above 76 kHz: 14,5611 Acquired: 2025/03/04 15.36.24 Total samples: 14367 Equivalent time: 0:11:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 6,1 dBr MIN: 3,5 dBr AVE: 5,12 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2025/03/04 15.36.24) 15.22 15.24 15.26 15.28 15.30 15.32 15.34 15.36 0 2 4 6 Pm [dBr]